| Manufacturer | Fluke |
|---|---|
| Place of Business | EVERETT, WA, 98203 US |
| Part number | FLUKE-561 |
| Item Weight | 300 g |
| Product Dimensions | 27.9 x 20.3 x 7.6 cm; 300 g |
| Batteries | 2 AAA batteries required. (included) |
| Item model number | FLUKE-561 |
| Is discontinued by manufacturer | No |
| Colour | Yellow |
| Power source type | Battery Powered |
| Item Package Quantity | 1 |
| Display Style | Digital |
| Special Features | Low Battery Indicator |
| Included components | Battery |
| Batteries Included? | Yes |
| Batteries Required? | Yes |
| Battery Cell Type | Lithium Ion |
| Length | 27.9 Centimetres |
| Width | 20.3 Centimetres |
| Height | 7.6 Centimetres |
-
-
-
-
-
-
-
VIDEO -
Image Unavailable
Colour:
-
-
-
- To view this video, download
Fluke 561 HVAC Pro Infrared Thermometer, 2 AA Battery,-40 to Plus 1022 Degree F Range
Purchase options and add-ons
| Brand | Fluke |
| Special feature | Low Battery Indicator |
| Colour | Yellow |
| Age range (description) | Adult |
| Included components | Battery |
| Outer material | Plastic |
| Display type | Digital |
| Connectivity technology | Infrared |
| Product care instructions | Wipe Clean |
| Unit count | 1 Count |
About this item
- Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in HVAC/R systems and manufacturing, electrical, and industrial environments
- Measures temperature from-40 to Plus 550 degrees C (-40 to Plus 1022 degrees F) with an accuracy of Plus or, 1 degree C ( Plus or, 2 degrees F) for the infrared sensor and an accuracy of Plus or, 2 degrees C ( Plus or, 4 degrees F) or 1-Percent of the reading, whichever is greater, for Type K thermocouple input
- 12:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area
- Included Type K thermocouple pipe probe wrapped in flexible hook-and-loop fastener with a 20-Inch cable takes contact measurements from 0 to 100 degrees C (32 to 212 degrees F)
- CE mark indicates compliance with applicable EU directives
Frequently bought together

From the manufacturer
Fluke Infrared Thermometers
Don't get burned by a motor, or have hot and cold air blowing in your face from your HVAC system or blowers while taking measurements. You can trust in Fluke infrared thermometers to get accurate temperature readings from a safe distance.
Fluke 561 Series Thermometers
Two-in-one IR and contact thermometers.
With Fluke 561 HVAC Thermometer, you can take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor-leave your ladder in the truck.
- IR thermometer for quick measurements up close, or at a distance, without a ladder
- Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
- Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
- Temperature range of -40°C to 550° C (-40°F to 1022°F) covers most industrial and residential applications
- Easy emissivity adjustment (Lo, Med, Hi) for measuring pipes and other shiny materials more accurately
- MIN, MAX, and DIF functions help you quickly identify problems
Benefits of the 561 HVAC Thermometer
Lighten up your toolbox. The Fluke 561 IR and contact thermometer, combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both infrared and contact temperature, replacing several other test tools. It’s fast, efficient, and easy to use, saving you valuable time and effort. With a rugged, easy-to-use, ergonomic design, the two-in-one contact and non-contact thermometers can stand up to tough industrial, electrical, mechanical, and HVAC environments. These tools go beyond other IR thermometers helping you work more efficiently in more applications.
Electrical Applications
Mechanical Applications
HVAC Applications
Contact Thermometer
Fluke 568
|
Fluke 566
|
Fluke 561
|
|
|---|---|---|---|
|
Add to Cart
|
Add to Cart
|
Add to Cart
|
|
| Customer Reviews |
4.4 out of 5 stars 39
|
4.6 out of 5 stars 21
|
4.4 out of 5 stars 222
|
| Infrared temperature rang | -40°C to 800°C (-40°F to 1472°F) | -40°C to 650°C (-40°F to 1202°F) | -40 to 550°C (-40 to 1022°F) |
| Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); whichever is greater | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); whichever is greater | no data |
| Thermocouple Type-K input temperature range | -270°C to 1372°C (-454°F to 2501°F) | -270°C to 1372°C (-454°F to 2501°F) | no data |
| D:S (distance to measurement spot size) | 50:1 | 30:1 | 12:1 |
| Data storage with date/time stamp | 99 points | 20 points | no data |
| Hi/Low alarms | Audible and two-color visual | Audible and two-color visual | no data |
| Min/Max/Avg/Dif | Yes | Yes | Yes |
| Backlight | Two levels, normal and extra bright for darker environments | Two levels, normal and extra bright for darker environments | Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options |
| Power | 2 AA/LR6 Batteries and USB when used with a PC | 2 AA/LR6 Batteries | 2 AA batteries (alkaline or NiCD) |
Product details
- Batteries : 2 AAA batteries required. (included)
- Is discontinued by manufacturer : No
- Product Dimensions : 27.9 x 20.3 x 7.6 cm; 300 g
- Date First Available : Aug. 7 2012
- Manufacturer : Fluke
- Place of Business : EVERETT, WA, 98203 US
- ASIN : B000WTHDUY
- Item model number : FLUKE-561
- 鶹 Rank: #99,940 in Industrial & Scientific (See Top 100 in Industrial & Scientific)
- #148 in Infrared Thermometers
- Customer Reviews:
Product information
Technical Details
Additional Information
| ASIN | B000WTHDUY |
|---|---|
| Customer Reviews |
4.4 out of 5 stars |
| 鶹 Rank |
|
| Date First Available | Aug. 7 2012 |
Feedback
Product description
The Fluke 561 dual infrared and thermocouple thermometer takes noncontact or contact temperature measurements in HVAC/R systems and manufacturing, electrical, and industrial environments. This thermometer measures temperature from-40 to Plus 550 degrees C (-40 to Plus 1022 degrees F) with an accuracy of Plus or-1 degree C ( Plus or-2 degrees F) for the infrared sensor and an accuracy of Plus or-2 degrees C ( Plus or-4 degrees F) or 1-Percent of the reading, whichever is greater, for Type K thermocouple input. It has a 12:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area. This thermometer comes with a Type K thermocouple pipe probe wrapped in flexible hook-and-loop fastener with a 20-Inch cable for taking contact measurements from 0 to 100 degrees C (32 to 212 degrees F), and it can accommodate any standard Type K thermocouple probe (sold separately). Its display shows the current temperature, the minimum, the maximum, the difference between the two temperatures, and the average temperatures when measured with the infrared sensor, and it has three emissivity settings that compensate for heat emitted from the surface of shiny objects to increase the accuracy of the measurement. Backlighting helps eliminate light reflections and improves contrast in low-light conditions. The European Conformity (CE) marking indicates compliance with applicable European Union (EU) directives. It comes with a Type K thermocouple pipe probe, a hard carrying case, two AA batteries and instructions. This thermometer is suitable for measuring the temperature of equipment, systems, and processes in HVAC/R (heating, ventilation, and air conditioning/refrigeration), industrial, electrical, and manufacturing environments. Specifications Temperature range -40 to Plus 550 degrees C (-40 to Plus 1022 degrees F) Infrared sensor accuracy <0 degrees C: Plus or, (1 degree C Plus 0.1 degree/1 degree C); > or = 0 degrees C: Plus or, 1-Percent of reading or Plus or, 1 degree C, whichever is greater (<32 degrees F: (2 degrees F Plus 0.1 degree/1 degree F); > or = 32 degrees F: Plus or, 1-Percent of reading or Plus or, 2 degrees F, whichever is greater Type K thermocouple input accuracy Plus or, 1-Percent of reading or Plus or, 2 degrees C ( Plus or, 1-Percent of reading or Plus or, 4 degrees F), whichever is greater Type K thermocouple input resolution 1 degree C/1 degree F Display resolution 0.1 degrees C/0.1 degrees F Distance-to-spot ratio 12:1 Type K flexible cuff thermocouple probe temperature range 0 to 100 degrees C (32 to 212 degrees F) Type K flexible cuff thermocouple accuracy Plus or, 2.2 degrees C ( Plus or, 4.0 degrees F) Power Supply (2) AA Batteries Weight 0.322kg/0.7099lb. Dimensions 17.69 x 5.18 x 16.36cm/6.965 x 2.039 x 6.441-Inch (H x W x D) H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back. Digital infrared thermometers measure the temperature of surfaces from a distance. They may measure temperature in Celsius, Fahrenheit, or both. Infrared (IR) thermometers work by focusing the infrared radiation emitted by a surface onto a detector called a thermopile. The thermopile turns the heat into electricity, which is measured and converted to a temperature reading. The reading is then displayed on an LCD display. IR thermometers are used to measure temperature when an object is fragile, as in ear thermometers, or dangerous to be near, as in the case of industrial equipment. Fluke Corporation manufactures electrical testing tools and software for industrial and commercial applications. The company, founded in 1948, is headquartered in Everett, WA. What's in the Box? Fluke 561 infrared thermometer Type K flexible cuff thermocouple probe Hard carrying case (2) AA batteries Instructions.